Dedicated circuit required for electric range or oven must be a 40 amp 240 volt circuit or have a.
Kitchen counter plugs code.
Kitchen counter top receptacle circuits.
Electrical code requirements for kitchen counter top receptacle circuits.
There is no danger to installing 15 amp outlet receptacles on a 20 amp circuit in fact this is the standard practice but under no circumstances should a 20 amp receptacle be installed on a 15 amp circuit.
Most of it however originates from people who work in the field.
When a kitchen island is present and the countertop is more than 24 inches wide or long the island must have at least one receptacle.
The kitchen code rules you need to worry about and those that local building inspectors will cite are the local codes but the model codes are helpful guides.
A 20 amp receptacle is designed to accept the special plug on heavier use appliances and if such an appliance plugs into a 15 amp circuit there is a danger of drawing too much power and.
The nec code requires at least two separate circuits to the kitchen counter top receptacles.
Islands with counter spaces separated by a cooktop or sink need two outlets one on either side.
Counter area receptacles may be no more than 20 inches above the countertop.
Small kitchen appliance cords such as coffee pots toasters and mixers rarely have a power cord that is more than 24 inches long.
If installed in the side of the island cabinet it can be no lower than 12 inches below the countertop surface.
The following is an explanation of the electrical code requirements for kitchen counter top receptacle circuits.